Polarity Center |
N/A Negative |
Input Voltage (AC) |
N/A 100 to 240 V |
Output Voltage (DC) |
N/A 5.9 V |
Output Current (DC) |
N/A 2.5 A |
Input Operating Frequency |
N/A 50 Hz60 Hz |
2007 EISA Efficiency |
N/A VI |
Length (L) |
N/A 0.433±0.020 in11 mm |
Inside Diameter (ID) |
N/A 0.083±0.004 in2.1 mm |
Outside Diameter (OD) |
N/A 0.217±0.004 in5.5 mm |
Alternating Current (AC) Input Voltage Range |
N/A 90 to 264 V |
Input Current at 115 VAC (Root Mean Square (RMS)) |
N/A <0.5 A |
Maximum Peak Inrush Current at 115 VAC (Cold Start) |
N/A <80 A |
Load Regulation |
N/A ±5 % |
Line Regulation |
N/A ±5 % |
Maximum Ripple and Noise (pk-pk) |
N/A 150 mV |
No-Load Power (Stand By) |
N/A <100 mW |
Average Efficiency |
N/A ≥82.39 % |
Note for Average Efficiency |
N/A Meets minimum level VI efficiency. |
Operating Temperature Range |
N/A 0 to 40 ºC |
Storage Temperature |
N/A -20 to 60 ºC |
Non-Condensing Humidity |
N/A 5 to 95 % |
Leakage Current at 264 VAC |
N/A <0.25 mA |
Maximum Dielectric Strength (Hi-Pot) |
N/A 5 mA |
Direct Current (DC) Dielectric Strength (Hi-pot) Per 3 Second (sec) Time |
N/A 4242 V |
Warranty |
N/A 5 years |
Case Type |
N/A Thermoplastic Molded Enclosure |
Long Nominal Output Cord Length |
N/A 5 ft18 AWG |
Safety and EMI |
N/A
UL: 62368-1 Class II, Double Insulated UL File Number: E345519 EMI standard: FCC part15 Subpart B, ICES-003 Issue 6, ANSI C63.4 2014 Over voltage and short circuit protected |
EISA 2007/CEC Compliance |
N/A All WSU Power Supplies manufactured after February 10, 2016 will meet the minimum efficiency levels for direct operation as defined by DOE Docket Number EERE 2008-BT-STD-0005-0219. Triad’s level VI products will have date code no later than 1605 (YYWW) where 16 is the year and 05 is the 5th week of 2016. In accordance with DOE requirement the label will also contain the Roman numeral VI with a circle. |