Print Back
  • 100-240V input w/interchangeable input plugs
  • 24W 5-24VDC Output
  • Level VI Efficiency
Unit of Measure

Check Stock

Click here to check stock >>

N/A

Specifications

Type

N/A Switchmode

2007 EISA Efficiency

N/A VI

Electrical Specifications at 25 Degree Celsius (ºC) Temperature

Input Voltage (AC)

N/A 100 to 240 V

Output Voltage (DC)

N/A 7.5 V

Output Current (DC)

N/A 2.4 A

Input Operating Frequency

N/A 50 to 60 Hz

Alternating Current (AC) Input Voltage Range

N/A 90 to 264 V

Input Current at 115 VAC (Root Mean Square (RMS))

N/A 0.7 A

Maximum Inrush Current at 115 VAC (Cold Start)

N/A 60 A

Line Regulation

N/A ±5 %

Load Regulation

N/A ±5 %

Maximum Ripple and Noise (pk-pk)

N/A 150 mV

Typical No-Load Power (Stand By)

N/A < 100 mW

Typical Efficiency at 10 Percent (%) Load

N/A 82.62 %

Average Efficiency

N/A 83.50 %

Note for Average Efficiency

N/A Typical Meets minimum level VI efficiency

Case Dimensions

Height (H)

N/A 3.02 in76.80 mm

Width (W)

N/A 1.87 in47.50 mm

Depth (D)

N/A 1.38 in35.00 mm

Output Plug Dimensions

Length (L)

N/A 0.433±0.020 in11 mm

Inside Diameter (ID)

N/A 0.083±0.004 in2.1 mm

Outside Diameter (OD)

N/A 0.217±0.004 in5.5 mm

Environmental Specifications

Operating Temperature at Full Load

N/A 0 to +45 ºC

Storage Temperature

N/A -20 to 60 ºC

Non-Condensing Relative Operating Humidity

N/A 5 to 95 %

Reliability Specifications

Leakage Current at 264 VAC

N/A < 0.25 mA

Dielectric Strength

N/A Hi-Pot - 4242 VDC/3 secs

Maximum Dielectric Strength (Hi-Pot)

N/A 5 mA

Warranty

N/A 5 years

Mechanical Parameters

Case Type

N/A Thermoplastic Molded Enclosure

Long Nominal Output Cord Length

N/A 6 ft18 AWG

Safety and EMI

Safety and EMI

N/A UL: 62368-1 Class II, Double Insulated
UL File Number: E345519
TUV: IEC 62368-1:2014 (Second Edition)
AS/NZS: AS/NZS 62368. 1:2018 and AS/NZS 3112 :2017
GS (S50452256): EN 62368-1: 2014 + A11
RCM: RCM201901745 Rev01
EMI standard: FCC part 15 Subpart B, ICES-003 Issue 6, ANSI C63.4-2014
Over voltage and short circuit protected

EISA 2007/CEC Compliance

EISA 2007/CEC Compliance

N/A This power supply meets the minimum efficiency requirements per Department of Energy and California Energy Commission.

RoHS Compliance

RoHS Compliance

N/A As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU, known as the RoHS 3 initiative.