Triad low-level audio transformers have been adopted as standard by many manufacturers of the finest in audio equipment. No other transformers offer such wide frequency range and such effective magnetic shielding in such small size. Shielding up to 95 db. is attained by multiple "Trialloy" cases interleaved with heavy copper shading rings. These transformers are solidly constructed, rigidly mounted with welded stainless steel studs, and hermetically sealed to MIL-T-27 specifications. Beautiful appearance, unmatched performance, long life, minimum size, are outstanding features of these quality transformers.
Applications |
N/A
Single Plate to P. P. Class A Grids. |
Note for Secondary Impedance |
N/A Center Tap |
Frequency Response Range |
N/A 20 to 20000 Hz |
Shielding |
N/A P-1 - One nickel alloy high permeability shield - 45 db. reduction in pickup. |
Case |
N/A GP-4 |
Primary Impedance |
N/A 15000 Ohm |
Secondary Impedance |
N/A 110000 Ohm |
Overall Turns Ratio |
N/A 1:1.36 |
DCR 1-2 |
N/A 821 Ohm |
DCR 3-4 |
N/A 2750 Ohm |
DCR 5-6 |
N/A 2750 Ohm |
Power Level |
N/A 75 mW |
Additional Information |
N/A
Avoid redesign - Use Triad HS and HSM transformers in military prototypes |