Print Back
Triad low-level audio transformers have been adopted as standard by many manufacturers of the finest in audio equipment. No other transformers offer such wide frequency range and such effective magnetic shielding in such small size. Shielding up to 95 db. is attained by multiple "Trialloy" cases interleaved with heavy copper shading rings. These transformers are solidly constructed, rigidly mounted with welded stainless steel studs, and hermetically sealed to MIL-T-27 specifications. Beautiful appearance, unmatched performance, long life, minimum size, are outstanding features of these quality transformers.
Unit of Measure

Check Stock

Click here to check stock >>

N/A

Specifications

Applications

N/A Universal Line or Mike to Grid.

Primary Impedance

N/A 62.5 Ohm150 Ohm250 Ohm600 Ohm

Note for Primary Impedance

N/A Balanced Center Tap. (600 and 250 Ohm)

Secondary Impedance

N/A 77000 Ohm

Overall Turn Ratio

N/A 1:11.3

Frequency Response Range

N/A 20 to 20000 Hz

Maximum Input Level

N/A 10 dBu

Shielding

N/A P-5 - Three nickel alloy shields interleaved with two heavy copper shading rings - 95 db. reduction in pickup.

Case

N/A GP-4

Additional Information

Additional Information

N/A Avoid redesign - Use Triad HS and HSM transformers in military prototypes

Triad HS and HSM series transformers are designed to meet MIL-T-27 requirements. Most of these transformers use standard MIL-T-27 case sizes. Exceptions are GP cases or any cases showing a Bw dimension, which may be classified as MIL-T-27 'YY' cases. Equipment using these transformers need not be redesigned to submit for military approval. The basically good design factors which are necessary to meet MIL-T-27 standards for performance ensure longest life in any class of service.

These transformers are permanently marked with electrical and test data as specified in MIL-T-27. All are "Climatite" treated, use sturdy TRIAD terminals and are beautifully finished in gray enamel.

Note

Note

N/A Low frequency loss will result from unbalanced DC in windings other than where specified.