Unit of Measure

Check Stock

Click here to check stock >>

Specifications

Polarity Center

Negative

Type

Switchmode

2007 EISA Efficiency

VI

Electrical Specifications at 25 Degree Celsius (ºC) Temperature

Input Voltage (AC)

100 to 240 V

Output Voltage (DC)

18.0 V

Output Current (DC)

1.33 A

Input Operating Frequency

50 to 60 Hz

Alternating Current (AC) Input Voltage Range

90 to 264 V

Input Current at 115 VAC (Root Mean Square (RMS))

0.7 A

Maximum Inrush Current at 115 VAC (Cold Start)

60 A

Line Regulation

±5 %

Load Regulation

±5 %

Maximum Ripple and Noise (pk-pk)

200 mV

Typical No-Load Power (Stand By)

<100 mW

Typical Efficiency at 10 Percent (%) Load

82.68 %

Average Efficiency

83.50 %

Note for Average Efficiency

Meets minimum level VI efficiency.

Case Dimensions

Height (H)

3.02 in76.80 mm

Width (W)

1.87 in47.50 mm

Depth (D)

1.38 in35.00 mm

Output Plug Dimensions

Length (L)

0.433±0.020 in11 mm

Inside Diameter (ID)

0.098±0.004 in2.5 mm

Outside Diameter (OD)

0.217±0.004 in5.5 mm

Environmental Specifications

Operating Temperature at Full Load

0 to +45 ºC

Storage Temperature

-20 to 60 ºC

Non-Condensing Relative Operating Humidity

5 to 95 %

Reliability Specifications

Leakage Current at 264 VAC

<0.25 mA

Dielectric Strength

Hi-Pot - 4242 VDC/3 secs

Maximum Dielectric Strength (Hi-Pot)

5 mA

Warranty

5 years

Mechanical Parameters

Case Type

Thermoplastic Molded Enclosure

Nominal Output Cord Length

6 ft22 AWG

Safety and EMI

Safety and EMI

UL: 62368-1 Class II, Double Insulated
UL File Number: E345519
TUV: IEC 62368-1:2014 (Second Edition)
AS/NZS: AS/NZS 62368.1:2018 & AS/NZS 3112:2017
GS (S50452256): EN 62368-1: 2014 + A11
RCM: RCM201901745 Rev01
EMI standard: FCC part15 Subpart B, ICES-003 Issue 6, ANSI C63.4-2014
Over voltage and short circuit protected

EISA 2007/CEC Compliance

EISA 2007/CEC Compliance

This power supply meets the minimum efficiency requirements per Department of Energy and California Energy Commission.

RoHS Compliance

RoHS Compliance

As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU, known as the RoHS 3 initiative.