Triad PC mount World Series transformers incorporate a dual bobbin construction with an insulating shroud, both made of a high temperature material that exceeds UL flammability requirements. These units are designed with very high isolation between the primary and secondary, and also, between each winding and the core. Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required. PC mount transformers are available with ratings from 2.5 VA 56.0 VA and have dimensionally accurate pin placement for through hole PC board mounting. All World Series transformers meet U.S. and International standards including CSA, IEC, TUV and UL requirements, and therefore have universal application.
Unit of Measure
Specifications
Electrical Rating |
N/A 2.5 V·A |
Secondary Series |
N/A 16.0 V CT at 0.15 A |
Secondary Parallel |
N/A 8.0 V at 0.3 A |
Transformer Contact Type |
N/A Center Tap |
Height (H) |
N/A 1 1/8 in |
Width (W) |
N/A 1 5/8 in |
Depth (D) |
N/A 1 5/16 in |
Dimension (A) |
N/A 0.200 in |
Dimension (B) |
N/A 0.250 in |
Dimension (C) |
N/A 1.000 in |
Pin Dimension |
N/A 0.025 in² |
Mounting Length |
N/A 1 1/16 in |
Primary Voltage |
N/A 115 V230 V |
Primary Frequency |
N/A 50 Hz60 Hz |
Industry Standards |
N/A CSA IEC TUV UL |
Weight |
N/A 0.30 lb |