Triad Magnetics’ Universal Chassis Mount power transformers are specially designed to offer optimal performance when integrated into full wave center tap circuits and bridge circuits, when those circuits utilize rectifiers made of silicon or selenium. They also perform excellently in voltage doubler circuits at half the rated current.

Universal Chassis Mount power transformers offer a huge array of nominal secondary voltages. For example, the F-90 series — the most capable models, designed for use with silicon diode rectifiers to supply DC voltages for transistors in innumerable applications — can generate 23 different output voltages, ranging from 7 V to 40 V, by connecting secondaries in a series. The secondary voltage is selected by primary taps.

View the table below for full Universal Chassis Mount Power Transformer specifications, or contact Triad Magnetics today to discuss your next project and its needs.

Unit of Measure
Items
Universal Chassis Mount Power Transformers

Universal Secondaries Chassis Mount Power Transformer

Universal Chassis Mount Power Transformers

Universal Secondaries Chassis Mount Power Transformer

Universal Chassis Mount Power Transformers (F-94X) - Case Type X

115 Volts (V) Chassis Mount Power Transformer

Universal Chassis Mount Power Transformers (F-94X) - Case Type X

115 Volts (V) Chassis Mount Power Transformer

Universal Chassis Mount Power Transformers (F-94X) - Case Type X

115 Volts (V) Chassis Mount Power Transformer
Description N/A Triad chassis mount power transformers provide maximum performance when integrated into full wave center tap or bridge type circuits with silicon or selenium rectifiers. The secondary voltages are selected by primary taps. The secondaries of the Series F-90 transformers may be connected to provide a wide variety of output voltages. The Series F-90 transformers are designed for use with silicon diode rectifiers to supply the DC voltages for transistors in their various applications. They are intended for use with full wave center tap or bridge rectifiers, but may be used with voltage doubler circuits at one-half of the rated current.
Click here to check stock >> N/A N/A N/A N/A N/A
Primary Voltage N/A 115 V230 V N/A 115 V230 V N/A 115 V N/A 115 V N/A 115 V
Secondary Voltage (AC) N/A 0 to 6.5 /13/19.5/26 V N/A 0 to 24/27/30/33/36 V N/A 10-20 CT-40 CT 14 to 40 (FWCT) 7 to 30 (FWB) N/A 10-20 CT-40 CT 14 to 40 (FWCT) 7 to 30 (FWB) N/A 10-20 CT-40 CT 14 to 40 (FWCT) 7 to 30 (FWB)
Transformer Contact Type N/A N/A N/A Center Tap N/A Center Tap N/A Center Tap
Secondary Current (AC) N/A 3.0 A N/A 3.0 A N/A N/A N/A
Secondary Current (DC)1 N/A N/A N/A 0.035 A N/A 0.1 A N/A 0.3 A
Case Type N/A U N/A U N/A X N/A X N/A X
Connections N/A Leads
Height (H) N/A 3 3/8 in N/A 3 3/4 in N/A 1 3/8 in N/A 1 5/8 in N/A 2 9/32 in
Width (W) N/A 2 13/16 in N/A 3 1/8 in N/A 2 3/8 in N/A 2 13/16 in N/A 3 11/16 in
Depth (D) N/A 2 5/8 in N/A 3 1/4 in N/A 1 3/8 in N/A 1 5/8 in N/A 2 in
Mounting Width N/A 2 1/4 in N/A 2 1/2 in N/A 2 in N/A 2 3/8 in N/A 3 1/8 in
Mounting Depth N/A 2 3/16 in N/A 2 5/8 in N/A N/A N/A
Mounting Hole Size N/A 13/64 x 3/8 in N/A 13/64 x 3/8 in N/A 3/16 in N/A 3/16 in N/A 3/16 in
Primary Frequency N/A 50 Hz60 Hz
Weight N/A 3.50 lb N/A 5.70 lb N/A 0.50 lb N/A 0.70 lb N/A 1.50 lb
Note N/A N/A N/A Tapped primary to produce lower voltages N/A Tapped primary to produce lower voltages N/A Tapped primary to produce lower voltages
Nominal Secondary Voltage N/A 6.5 V13 V19.5 V26 V N/A 24 V27 V30 V33 V36 V N/A 7 V7.5 V8 V8.5 V9.5 V10 V14 V15 V16 V17 V19 V20 V21 V22.5 V24 V25.5 V28 V28.5 V30 V32 V34 V38 V40 V N/A 7 V7.5 V8 V8.5 V9.5 V10 V14 V15 V16 V17 V19 V20 V21 V22.5 V24 V25.5 V28 V28.5 V30 V32 V34 V38 V40 V N/A 7 V7.5 V8 V8.5 V9.5 V10 V14 V15 V16 V17 V19 V20 V21 V22.5 V24 V25.5 V28 V28.5 V30 V32 V34 V38 V40 V
Secondary Voltage-Series Connection N/A
Secondary Voltage-Parallel Connection N/A
  • 1 DC amp rating with a full wave bridge rectifier hi-pot tested at 1,500 VRMS.