Due to the nature of their use, medical equipment can be extremely sensitive and have highly precise requirements that their components need to meet.
Triad Magnetics has extensive experience in manufacturing medical grade transformers. Triad’s Toroidal Medical power transformers are ideal transformers for a range of medical applications and, with more than 45 models available, we have a transformer for each of them.
Our toroidal construction medical power transformers, with dual secondary cores to allow for both series and parallel connections, maintain low leakage current, low stray fields, regulation between 0.7% and 12.3%, and low temperatures rises of only 25ºC to 55ºC.
To learn more about our Toroidal Medical power transformers — including electrical ratings, power range, secondary voltage while in a parallel connection, and secondary voltage while in a series — consult the specifications table below or contact Triad Magnetics today.
Items |
/Asset/vpm240-200.jpg VPM12-2080 25 Voltage·Ampere (V·A) Power VPM Series Toroidal Medical Transformer |
/Asset/vpm240-200.jpg VPM18-1390 25 Voltage·Ampere (V·A) Power VPM Series Toroidal Medical Transformer |
/Asset/vpm240-200.jpg VPM24-1040 25 Voltage·Ampere (V·A) Power VPM Series Toroidal Medical Transformer |
/Asset/vpm240-200.jpg VPM30-830 25 Voltage·Ampere (V·A) Power VPM Series Toroidal Medical Transformer |
/Asset/vpm240-200.jpg VPM36-690 25 Voltage·Ampere (V·A) Power VPM Series Toroidal Medical Transformer |
|||||
Click here to check stock >> | N/A | N/A | N/A | N/A | N/A | |||||
Electrical Rating | N/A 25 V·A | |||||||||
Typical Regulation | N/A 10.5 % | N/A 10.3 % | N/A 10.3 % | N/A 10.3 % | N/A 11.1 % | |||||
Typical Efficiency | N/A | |||||||||
Typical Temperature Rise | N/A 25 ºC | |||||||||
Secondary Voltage in Series | N/A 12 V CT at 2.08 A | N/A 18 V CT at 1.39 A | N/A 24 V CT at 1.04 A | N/A 30 V CT at 0.83 A | N/A 36 V CT at 0.69 A | |||||
Secondary Voltage in Parallel | N/A 6.0 V at 4.16 A | N/A 9.0 V at 2.78 A | N/A 12 V at 2.08 A | N/A 15 V at 1.66 A | N/A 18 V at 1.38 A | |||||
Outside Diameter | N/A 84 mm | |||||||||
Weight | N/A 0.5 kg | |||||||||
Primary Frequency | N/A 50 Hz60 Hz | |||||||||
Secondary Connection Type | N/A Parallel Series | |||||||||
Insulation Class | N/A Class F, 155 ºC | |||||||||
Dielectric Isolation (Primary to Secondary) for 60 seconds | N/A 4 kV | |||||||||
Industry Standards | N/A CE CRU®US | |||||||||
Nominal Primary Voltage | N/A 100 V120 V220 V240 V | |||||||||
Nominal Secondary Voltage | N/A 6 V12 V | N/A 9 V18 V | N/A 12 V24 V | N/A 15 V30 V | N/A 18 V36 V | |||||
Secondary Power (Volts x Amp=VA) | N/A 25 V·A | |||||||||
Connection Type | N/A Leads | |||||||||
Safety | N/A Medical | |||||||||
Maximum Height | N/A 37 mm | |||||||||
Note |
N/A
Custom designs available. RoHS Compliance: As of manufacturing date February 2016, all standard products meet the requirements of 2015/863/EU, known as the RoHS 3 initiative. Upon printing, this document is considered "uncontrolled". |
|||||||||
|