TLD1020/40 Series - 20-40 Watt (W) Single Output Encapsulated Switching Power Supplies
Power Supplies & LED Drivers
20-40 Watt Single Output Encapsulated Switching Power Supply with PFC for Indoor & Outdoor IP66/NEMA 4 Applications
Unit of Measure
Items |
/Asset/a1460.jpg TLD1020-12 TLD1020/40 Series - 20-40 Watt (W) Single Output Encapsulated Switching Power Supplies |
/Asset/a1460.jpg TLD1020-24 TLD1020/40 Series - 20-40 Watt (W) Single Output Encapsulated Switching Power Supplies |
/Asset/a1460.jpg TLD1040-12 TLD1020/40 Series - 20-40 Watt (W) Single Output Encapsulated Switching Power Supplies |
/Asset/a1460.jpg TLD1040-24 TLD1020/40 Series - 20-40 Watt (W) Single Output Encapsulated Switching Power Supplies |
/Asset/a1460.jpg TLD1020-24-C0350 TLD1020/40 Series - 20-40 Watt (W) Single Output Encapsulated Switching Power Supplies |
|||||
Description | N/A 20-40 Watt Single Output Encapsulated Switching Power Supply with PFC for Indoor & Outdoor IP66/NEMA 4 Applications | |||||||||
Click here to check stock >> | N/A | N/A | N/A | N/A | N/A | |||||
Type | N/A Constant Voltage Models | N/A Constant Voltage Models | N/A Constant Voltage Models | N/A Constant Voltage Models | N/A Constant Current Models | |||||
Voltage | N/A 12 V | N/A 24 V | N/A 12 V | N/A 24 V | N/A 12 to 24 V (DC) | |||||
Current | N/A 1.66 A | N/A 0.83 A | N/A 3.33 A | N/A 1.67 A | N/A | |||||
Current (DC) | N/A | N/A | N/A | N/A | N/A 350 mA | |||||
Efficiency | N/A 84 % | |||||||||
Input Voltage (AC) | N/A 100 to 304 V | |||||||||
Input Frequency Range | N/A 47 to 63 Hz | |||||||||
Power Factor | N/A 0.9 at Full Load & 115 VAC | |||||||||
Maximum Crest Factor (Ipk) | N/A 1.5 | |||||||||
Maximum Input Current at 115/230 VAC | N/A 0.15 A0.3 A | N/A 0.15 A0.3 A | N/A 0.25 A0.5 A | N/A 0.25 A0.5 A | N/A 0.15 A0.3 A | |||||
Maximum Inrush Current at 115 / 230 VAC (Cold Start) | N/A 5 A10 A | |||||||||
Adjustable Output Range | N/A Fixed | |||||||||
Set Point Accuracy | N/A ±5 % | |||||||||
Current Accuracy | N/A ±1% (when applicable) | |||||||||
Ripple and Noise | N/A ±5 % | |||||||||
Load Regulation | N/A ±3.0 % | |||||||||
Line Regulation | N/A ±3.0 % | |||||||||
Minimum Hold-up Time, at 120 VAC & 80% Load | N/A 1/2 Cycle | |||||||||
Over Current Protection (Auto-recovery) | N/A 120 % | |||||||||
Over Voltage Protection (Auto-recovery) | N/A 120 % | |||||||||
Length (L) | N/A 3.74 in95 mm | |||||||||
Width (W) | N/A 1.57 in40 mm | N/A 1.57 in40 mm | N/A 2.76 in70 mm | N/A 2.76 in70 mm | N/A 1.57 in40 mm | |||||
Height (H) | N/A 0.97 in25 mm | N/A 0.97 in25 mm | N/A 1.260 in32 mm | N/A 1.260 in32 mm | N/A 0.97 in25 mm | |||||
Weight | N/A 120 g | |||||||||
Reliability (MTBF) | N/A >100k hrs. (Full Load & 25 ºC Operation) | |||||||||
Warranty | N/A 3 years | |||||||||
Operating Temperature | N/A -30 to +60 Full Load, derate 1%/ºC from 60 to 70 max ºC | |||||||||
Storage Temperature | N/A -40 to +85 ºC | |||||||||
Cooling | N/A Convection Cooled Operation | |||||||||
Humidity | N/A 5 to 95 % RH, non-condensing | |||||||||
Vibration | N/A 5 to 50 Hz, 2G 1 min/cycle, period of 60 min, each axis. | |||||||||
EMC Emissions | N/A Compliant to 47CFR, Part 2, Part 15 and Cispr PUB, 22 | |||||||||
Class B Safety Approval | N/A CE Mark (LVD) UL/cUL 1310 UL48 | |||||||||
Input Wire | N/A 18 AWG | |||||||||
Input Leads | N/A 5 in | |||||||||
Output Wire | N/A 18 AWG | |||||||||
Output Leads | N/A 5 in | |||||||||
|